AES-200 Advantages and Benefits

  • Can be used in moist areas
  • Adheres to a variety of substrates
  • Excellent resistance to solvents, hydrocarbons, acids, alkalis
  • Highly impact resistant
  • Excellent adhesion
  • Flexible properties withstand extremely abrasive conditions
  • Slip resistance
  • Thermal shock resistance

For further assistance, contact one of our technicians via phone or by email.

SAFETY

This product (and any recommended thinners) contains solvents and/or chemical ingredients. Adequate health and safety precautions should be observed during storage, handling, use, and drying periods. For safe usage, user is specifically directed to consult the current Material Safety Data Sheet for this product. When using this product in a confined space or closed area, consult the OSHA or ANSI bulletins on safety requirements.

Storage & Handling

Download MSDS Sheet for AES-250 Floor Coating Part "A" & "B"

Download Spec Sheet for AES-250 Floor Coating

For emergency information contact CHEMTREC at 1-800-424-9300.

AES-250 Epoxy Floor Coating

Description:

AES-250 is tough and flexible protective coating for concrete. AES-250 is a 100% solid Polyamide epoxy resin used in applications where chemical and corrosion resistance is required.

Resistance:

AES-250 is highly resistant to acids, solvents, caustics, hydrocarbons, freshwater, and saltwater. It was developed to withstand extreme corrosive and abrasive conditions, with excellent outdoor durability.

Application Areas:

AES-250 is excellent as an anti-corrosive and protective coating for concrete floors and structures. AES-250 retains a resilient body, even after final cure. It can even be used under constant spillage and highly abrasive applications. AES-250 is used in commercial, industrial, and residential surroundings.

Preparation:

To begin, the surface should be etched to provide a profile or “tooth” for optimal adhesion.  Surfaces must be cleaned free of grease, oil, wax, mastic compounds,

paint, waterproofing compounds, form release materials, and all other contaminants prior to application.

New concrete and masonry should not be coated for at least 28 days to permit the concrete or mortar to cure and dry out.  Concrete should be visually inspected and tested for moisture content before coatingAES-250 will not develop optimum adhesion to concrete unless Latinate and other loosely bound materials are first removed from the surface.  Latent must be removed by abrading.  Shot blasting, scarifying, grinding, sand-blasting or other abrasive mechanical means are recommended.  Acid etching is an option but not recommended because of environmental concerns or accidental damage to non-target areas.

For aged concrete, remove old coatings and/or other materials previously applied.  Abrasive or mechanical means are recommended.  Infiltration of oil, grease, gas, etc. into the concrete will retard adhesion.  Contaminated concrete must be sufficiently removed or thoroughly cleaned with a cleaning agent appropriate for the removal of petroleum-based products.  After the surface cleansing, continue on with directions for the new concrete application.

The preparation procedures above are general guidelines. Detailed preparation methods are available through SSPC at www.sspc.org or NACE at www.nace.org.

Mixing:

The mixing of Part A and B is very important!  Material is supplied in two containers as a unit. 

Agitate part B separately in container supplied before pouring. AES-250 has a (1:1) mixing ratio of 1 part “B” to 1 part “A”.  Use a jiffy mixer to thoroughly combine both parts, mixing for 1 minute per gallon. Allow idle activation time for at least 2 minutes.

 

Thinning:

If thinning is necessary, use no more than 1 pint of Xylene per 2 gallon of epoxy. Thinner can only be added after activation process is completed. Thinning will extend pot life and retard curing time.

Application:

Apply AES-250 with a brush, 3/8” nap roller or airless spray equipment.   Caution!  Without the use of aggregate, AES-250 is slippery when wet. Apply only when air temperature is 40° F and rising.


DRY FILM APPLICATIONS

To get dry film of:                    Apply Sq. Ft. /gal.

8 mils                                     200 sq ft

16 mils                                 100 sq ft

 

DO NOT apply product heavier than (8 wet mils) on vertical surfaces. Heavy coats may be applied (up to 16 mils) on horizontal surfaces without danger of bubbling or pinholes in film.  For heavier film, apply additional coats.  Additional coats must be applied as soon as the surface is tack free or within 36 hours.

 

Clean Up:

Application equipment should be cleaned immediately with Xylene.  Use white vinegar to clean hands and skin.  Do not allow AES-250 to remain on tools!  Once it sets and is cured, it is extremely difficult to remove.

 

Curing Time:     

Pot-Life:                         1hr @ 80 ºF

Drying Time:                    5 hrs @ 80 ºF

Complete:                       48 hrs @ 80 ºF

 

Packaging:

2-gallon units:

  1. 1 gal can containing Base

     (Part “B”)

  1. 1 gal can containing Activator

          (Part “A”)

Also available in 10 gallon units.

 

Colors:    AES Standard Colors (Gray & Tan in different shades)

                 Custom colors are available

 Solids content:      100% Solids

 

Mixing Ratio:         1 parts “B” to 1 part “A” (1:1)

 

Abrasion Resistance (ASTM D4060):

Taber abraser CS-17 calibrase wheel at 4000 cycles with 1.7 mils wear and .28 grams lost.

 

Compression (C579-96):  4500 psi

 

Adhesion-Pull-Off (D4541):  Concrete: 100 % substrate failure @ 1177 psi

 

Impact Resistance (D2794):  36 inch lbs. direct - passed

 

Pencil Hardness (D3363):       5H – passed

 

Food Contact    FDA 21-CFR 175-300 Compliant

 

For further assistance, contact one of our technicians via phone or e-mail.

MSDS are available for health and safety data.

 

For emergency information contact:

CHEMTREC @ 1-800-424-9300

 

Safety:

This product (and any recommended thinners) contains solvents and/or chemical ingredients.  Adequate health and safety precautions should be observed during storage, handling, use, and drying periods.  For safe usage, user is specifically directed to consult the current Material Safety Data Sheet for this product.  When using this product in a confined space or closed area, consult the OSHA or ANSI bulletins on safety requirements.

The information as set forth in the technical data contained herein has been developed based on test and evaluations made by Advanced Epoxy Systems, Inc. for standard coating applications.  We believe this information is the best currently available on the subject.  We make no guarantee of results and assume no obligation or liability in connection with this information.  It is offered as possible helpful suggestion, any experimentation you may care to undertake along these lines, is at your own risk.  You should test the coating material to determine if it is suitable for the application intended.  It is supplied on the condition that you shall make your own tests to determine its suitability.  AES shall have no liability for incidental or consequential damages, indirect or direct.  Our liability is limited to the net selling price of the purchased product(s) or the replacement of our product, at our option.